Build Your Online Product Catalogs?
Product Name: |
Medical POCT Fluorescence immunoassay analyzer laboratory quanti
|
Supply Ability: |
1000000 pieces |
Related proudcts |
diagnostic, poct, fluorescence immunoa, |
Specifications |
1 set per carton |
Price Term: |
FOB |
Port of loading: |
SHANGHAI |
Minimum Order |
1 SET |
Unit Price: |
$850 |
|
Fluoroimmunoassay (FIA) is a kind of trace analysis method developed
in recent years. It also is one of the most sensitive trace analysis
technologies for now. Certain substances molecules can absorb energy
and emit fluorescence, do qualitative or quantitative analysis on
substances depending on the fluorescence spectra and fluorescence
intensity, this method is called fluorescence analysis.
FIA has advantages of high sensitivity, strong selectivity, small sample
volume and simple methods, and usually its lower limit is 2-4
magnitude higher than spectrophotometry, it is widely used for
biochemical analysis.
Features:
1.Fast-under continuous mode,over 200 Tests/Hour,under step mode,only 3 mins/test
2.Intelligent -under intelligent mode,it can ***ect automatically without manual operation
3.Report- Built-in printer,it can print result of multi-parameters one time.
4.Storage- It can store over 10,000 kinds of test results
5.Accurate- Multi-times quality control to make sure test results much more accurate
6.Connection- Connecting to LIS by COM or USB etc.
Product Performance
a) Sensitivity
The minimum ***ectable amount for CRP is 0.5mg/L.
b) Linear range
For the range of CRP 0.5 mg/L¡«200mg/L, the correlation coefficient r ¡Ý 0.98.
c) Accuracy
In the range of CRP 0.5mg/L¡«5mg/L(include 5): Error does not exceed ¡À15£¥.
In the range of CRP 5mg/L¡«200mg/L: Error does not exceed ¡À10£¥.
Repeatability: CV¡Ü5£¥
Stability: CV¡Ü5£¥
Structure and Principles
1 .Main Structure
The analyzer is composed of optical inspection (light source, filter,
sample room, photocell, signal amplification and conversion), SCM
analysis and control, display and print.
2 .Working Principle
When the test card that has been added sample is inserted in the
Fluorescence Immunoassay Quantitative Analyzer, LED light source
irradiate test area and control area of the test card, excite attached
fluorescent substance, emitted light is collecte |