Intended Use
The reagent is used to ***ect the Hepatitis C Virus Antibody in serum / plasma qualitatively.
Test Principle
The test utilizes antibodies including a recombinant protein mixed HCV antigen and rabbit anti-HCVantibody on the nitrocellulose membrane with colloidal gold marked mixed HCV antigen as a mark tracer. The reagent is used to ***ect the HCV antibody in serum / plasma according to the principle of double antigen sandwich method and gold immunochromatography assay. The sample mixing up HCV antigen¨Cmarker move along the membrane to the T line, and form the Tline when the sample contains HCV antibody,which a positive result. Conversely, it is a negativeresult.
Main Components
Sample pad, colloidal gold marked pad, nitrocellulose membrane, absorbent paper and PVC board.
Storage and Expiry Store as packaged in the sealed pouch at 4-30℃, avoid hot and sunshine, dry place, valid for 24 months. DO NOT FREEZE. Some protective measures should be taken in hot summer and cold winter to avoid high temperature or freeze-thaw.
Sample Requirement
1. The reagent can be used for the serum, plasma samples. After collection, separate the serum and plasma as soon as possible, in order to avoid hemolysis. 2. A serum / plasma sample must be collected in a clean and dry container. EDTA, sodium citrate, sodium oxalate, heparin can be used as the anticoagulants. ***ect immediately after collecting blood. If blood coagulation occurs, serum samples are suggested to use. 3. Samples may be stored at 2-8℃ for 3 days prior to assay, and at -20 ℃.
Test Procedure
Instructions must be read entirely before taking the test. Allow the test device controls to equilibrate to room temperature for 30 minutes (20℃-30℃) prior to testing. Do not open the inner packaging until ready, it must be used in one hour if opened (Humidity: 20%~90%, Temp:10℃-50℃)
Strip and Cassette:
1. Take off the outer packing, put the strip/cassette onto the desk with the sample adding area of the strip/ the s |